Learning Advanced Features
Ad
50
E-Save Mode 1 Manual - -
51
Energy Save 30 0–30 %
5.14.2 Automatic Energy Saving Operation
The amount of energy saving can be automatically calculated based on the rated motor current
(bA.13) and the no-load current (bA.14). From the calculations, the output voltage can be adjusted.
Ad 50
E-Save Mode 2 Auto - -
If operation frequency is changed or acceleration and /deceleration is carried out by a stop command
during the energy saving operation, the actual Acc/Dec time may take longer than the set Acc/Dec
time due to the time required to return to the gerneral operation from the energy saving operation.
5.15 Speed Search Operation
This operation is used to prevent fault trips that can occur while the inverter output voltage is
disconnected and the motor is idling. Because this feature estimates the motor rotation speed
based on the inverter output current, it does not give the exact speed.
Cn
69
PM speed search pulse
current
SS Pulse Curr 15 10~100 %
70
Speed search mode
SS Mode
- -