EasyManua.ls Logo

LSIS LSLV-S100 - Navigating Directly to Different Codes

LSIS LSLV-S100
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
Learning to Perform Basic Operations
Note
For some settings, pressing the [] or [] key will not increase or decrease the code number by 1.
Code numbers may be skipped and not be displayed. This is because certain code numbers have been
intentionally left blank (or reserved) for new functions to be added in the future. Also some features
may have been hidden (disabled) because a certain code has been set to disable the functions for
relevant codes.
As an example, if Ad.24 (Frequency Limit) is set to 0 (No), the next codes, Ad.25 (Freq Limit Lo) and
Ad.26 (Freq Limit Hi), will not be displayed. If you set code Ad.24 to 1 (Yes) and enable the frequency
limit feature, codes Ad.25 and 26 will appear to allow the maximum and minimum frequency
limitations to be set up.
3.2.2 Navigating Directly to Different Codes
The following example details navigating to code dr. 95, from the initial code in the Drive group (dr.
0). This example applies to all groups whenever you would like to navigate to a specific code
number.
Step
Instruction
Keypad Display
1
Ensure that you are currently at the first code of the Drive group
(dr.0).
2
Press the [ENT] key.
Number ‘9’ will flash.
3
Press the [] key to display 5, the first 1s place of the group
destination, 95.
4
Press the [] key to move to the 10s place.
The cursor will move to the left and ‘05’ will be displayed. This time,
the number ‘0’ will be flashing.
(
%
)5
dr.0

Table of Contents

Other manuals for LSIS LSLV-S100

Related product manuals