EasyManua.ls Logo

LSIS LSLV-S100 - Multi-Function Output On;Off Control

LSIS LSLV-S100
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
190
Learning Advanced Features
5.32 Multi-Function Output On/Off Control
Set reference values (on/off level) for analog input and control output relay or multi-function
output terminal on/off status accordingly.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Ad
66
Output terminal on/off
control mode
On/Off Ctrl Src 1 V1 - -
67 Output terminal on level On-C Level 90.00
Output terminal
off level 100.00%
%
68 Output terminal off level Off-C Level 10.00
0.00
Output
terminal on level
%
OU
31
Multi-function relay1
item
Relay 1
34
On/Off - -
33
Multi-function output1
item
Q1 Define
Multi-function Output On/Off Control Setting Details
Code
Description
Ad.66 On/Off Ctrl Src Select analog input On/Off control.
Ad.67 On-C Level ,
Ad.68 Off-C Level
Set On/Off level at the output terminal.