Code
Name LCD Display Setting Range
V/F SL Ref.
94
42
0h145E
weakening start
SL FW Freq 80.0-110.0(%) 100.0 X/A X I p.147
95
42
0h145F
switching
SL Fc Freq 0.00-8.00(Hz) 2.00 X/A X I p.147
8.6 Input Terminal Block Function group (PAR→In)
In the following table, the data shaded in grey will be displayed when a related code has been
selected.
SL: Sensorless vector control (dr.09) , I – IM Sensorless, P – PM Sensorless
*O/X: Write-enabled during operation, 7/L/A: Keypad/LCD keypad/Common
Code
Name LCD Display Setting Range
Property*
V/F SL Ref.
01 0h1501
Frequency for
maximum
analog input
Freq at 100%
Start frequency-
Maximum
frequency(Hz)
um
freque
O/A O I/P p.67
02 0h1502
maximum
Torque
at100%
0.0-200.0(%) 100.0 O/A X X -
05 0h1505
voltage
V1 Monitor(V) -12.00-12.00(V) 0.00 -/A O I/P
p.67
06 0h1506
polarity
selection
V1 Polarity
Unipola
r
X/A O I/P p.67
1 Bipolar
07 0h1507
of V1 input
V1 Filter 0-10000(ms) 10 O/A O I/P p.67
08 0h1508
V1 Volt x1 0.00-10.00(V) 0.00 O/A O I/P p.67
09 0h1509
Minimum
V1 Perc y1 0.00-100.00(%) 0.00 O/A O I/P p.67
10 0h150A
V1 Volt x2 0.00-12.00(V) 10.00 O/A O I/P p.67