Code
Name LCD Display Setting Range
Property*
V/F SL Ref.
11 0h150B
Maximum
V1 Perc y2 0.00-100.00(%) 100.00 O/A O I/P p.67
12
43
0h150C
V1 –Volt x1’
-10.00- 0.00(V) 0.00 O/A O I/P p.70
13
43
0h150D
Minimum
V1 –Perc y1’ -100.00-0.00(%) 0.00 O/A O I/P p.70
14
43
0h150E
V1 –Volt x2’
-12.00- 0.00(V) -10.00 O/A O I/P p.70
15
43
0h150F
Maximum
V1 –Perc y2’
-100.00-0.00(%) -100.00 O/A O I/P p.70
16 0h1510
direction
V1 Inverting
0: No O/A O I/P p.67
1 Yes
17 0h1511
quantization
V1 Quantizing
0.00
44
, 0.04-
10.00(%)
0.04 X/A O I/P p.67
35
45
0h1523
voltage
V2 Monitor(V) 0.00-12.00(V) 0.00 -/A O I/P p.74
37
45
0h1525
V2 input filter
time constant
V2 Filter 0-10000(ms) 10 O/A O I/P p.74
38
45
0h1526
V2 Volt x1 0.00-10.00(V) 0.00 O/A X I/P p.74
39
45
0h1527
Minimum
V2 Perc y1 0.00-100.00(%) 0.00 O/A O I/P p.74
40
45
0h1528
V2 Volt x2 0.00-10.00(V) 10 O/A X I/P p.74
41
45
0h1529
Maximum
V2 Perc y2 0.00-100.00(%) 100.00 O/A O I/P p.74
46
45
0h152E
direction
V2 Inverting
0:No O/A O I/P p.74
1 Yes
47
45
0h152F
V2
quantization
V2 Quantizing
0.00
44
, 0.04-
0.04 O/A O I/P p.74
43
Displayed when In.06 is set to 1 (Bipolar).
44
Quantizing is not used when set to 0.
45
Displayed when V is selected on the analog current/voltage input circuit selection switch (SW2).