56
Learning to Perform Basic Operations
3.3.5 Frequency Setting (Keypad) and Operation (via Terminal Input)
Step
Instruction
Keypad Display
1
Turn on the inverter.
-
2
Ensure that the first code of the Operation group is selected, and
code 0.00 (Command Frequency) is displayed, then press the
[ENT] key.
The first digit on the right will flash.
3
Press the [] key 3 times to go to the 10s place position.
The number 0’ at the 10s place position will flash.
4
Press the [] key to change it to 1, and then press the [ENT] key.
The parameter value (10.00) will flash.
5
Press the [ENT] key once again to save changes.
A change of reference frequency to 10.00 Hz has been completed.
6
Refer to the wiring diagram at the bottom of the table, and close
the switch between the P1 (FX) and CM terminals.
The RUN indicator light flashes and the FWD indicator light comes
on steady. The current acceleration frequency is displayed.
7
When the frequency reference is reached (10Hz), open the switch
between the P1 (FX) and CM terminals.
The RUN indicator light flashes again and the current deceleration
frequency is displayed. When the frequency reaches 0Hz, the RUN
and FWD indicator lights turn off, and the frequency reference
(10.00Hz) is displayed again.
[Wiring Diagram] [Operation Pattern]
Note
The instructions in the table are based on the factory default parameter settings. The inverter may not
work correctly if the default parameter settings are changed after the inverter is purchased. In such
cases, initialize all parameters to reset the values to factory default parameter settings before following
the instructions in the table (refer to 5.23 Parameter Initialization on page 181).