Learning to Perform Basic Operations
1
Go to code 0 (Jog Frequency) in the Drive group.
2
Press the [ENT] key.
The current parameter value (9) will be displayed.
3
Press the [q] key to change the first place value to ‘3’ of the target
code, ’93.’
4
Press the [◀] key to move to the 10s place position.
‘03’ will be displayed.
5
Press the [▲] or [▼] key to change the ‘0’ to ‘9’ of the target
code, ’93.’
6
Press the [ENT] key.
Code dr.93 will be displayed.
7
Press the [ENT] key once again.
The current parameter value for code dr.93 is set to 0 (Do not
8
Press the [▲] key to change the value to 1 (All Grp), and then press
the [ENT] key.
The parameter value will flash.
9
Press the [ENT] key once again.
Parameter initialization begins. Parameter initialization is complete
when code dr.93 reappears on the display.
Following parameter initialization, all parameters are reset to factory default values. Ensure that
parameters are reconfigured before running the inverter again after an initialization.