81
Learning Basic Features
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Operation
drv
Command source
Cmd Source*
1
Fx/Rx-1
05
-
In
6571
Px terminal
configuration
Px Define(Px: P1
P7)
1
Fx
054 -
2
Rx
* Displayed under DRV-06 on the LCD keypad.
Fwd/Rev Command by Multi-function Terminal Setting Details
Code
Description
Operation group
drvCmd Source
Set to 1(Fx/Rx-1).
In.6571 Px Define
Assign a terminal for forward (Fx) operation.
Assign a terminal for reverse (Rx) operation.
4.5.3 Terminal Block as a Command Input Device (Run and Rotation
Direction Commands)
Multi-function terminals can be selected as a command input device. This is configured by setting
the drv (command source) code in the Operation group to 2(Fx/Rx-2). Select 2 terminals for run
and rotation direction commands, and then select the relevant codes (2 of the 5 multi-function
terminal codes, In.6571 for P1P7) to 1(Fx) and 2(Rx) respectively. This application uses an Fx input
as a run command, and an Rx input to change a motors rotation direction (On-Rx, Off-Fx).
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Operation
Drv
Command source
Cmd Source*
2
Fx/Rx-2
05
-
In
6571
Px terminal
configuration
Px Define (Px: P1
P7)
1
Fx
054 -
2
Rx
* Displayed under DRV-06 on the LCD keypad.