115
Learning Basic Features
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
80 User function output 16 User Output 16 0
-3276732767
-
81 User function 17 User Func17 0
028
-
82 User function input 17-A User Input 17-A 0
00xFFFF
-
83 User function input 17-B User Input 17-B 0
00xFFFF
-
84 User function input 17-C User Input 17-C 0
00xFFFF
-
85 User function output 17 User Output 17 0
-3276732767
-
86 User function 18 User Func18 0
028
-
87 User function input 18-A User Input 18-A 0
00xFFFF
-
88 User function input 18-B User Input 18-B 0
00xFFFF
-
89 User function input 18-C User Input 18-C 0
00xFFFF
-
90 User function output 18 User Output 18 0
-3276732767
-
User Sequence Setting Details
Code
Description
AP.02 User Seq En
Display the parameter groups related to a user sequence.
US.01 User Seq Con
Set Sequence Run and Sequence Stop with the keypad.
Parameters cannot be adjusted during an operation. To adjust parameters,
the operation must be stopped.
US.02 User Loop Time
Set the user sequence Loop Time.
User sequence loop time can be set to 0.01s/0.02s/ 0.05s/0.1s/0.5s/1s.
US.1128
Link UserOut118
Set parameters to connect 18 Function Blocks. If the input value is 0x0000,
an output value cannot be used.
To use the output value in step 1 for the frequency reference (Cmd
Frequency), input the communication address(0x1101) of the Cmd
frequency as the Link UserOut1 parameter.
US.3160 Void Para130
Set 30 void parameters. Use when constant (Const) parameter input is
needed in the user function block.
UF.0190
Set user defined functions for the 18 function blocks.
If the function block setting is invalid, the output of the User Output@ is -1.
All the outputs from the User Output@ are read only, and can be used with
the user output link@ (Link UserOut@) of the US group.
Function Block Parameter Structure
Type
Description
User Func @*
Choose the function to perform in the function block.
User Input @-A
Communication address of the functions first input parameter.
User Input @-B
Communication address of the functions second input parameter.
User Input @-C
Communication address of the functions third input parameter.