Learning Advanced Features
Auxiliary Reference Operation Ex #2
Keypad Frequency Setting is Main Frequency and I2 Analog Voltage is Auxiliary Frequency
• Main frequency: Keypad (Operation frequency 30Hz)
• Maximum frequency setting (dr.20): 400Hz
• Auxiliary frequency setting (bA.01): I2 [Display by percentage(%) or auxiliary frequency(Hz)
depending on the operation setting condition]
• Auxiliary reference gain setting (bA.03): 50%
• In.01–32: Factory default
Example: an input current of 10.4mA is applied to I2, with the frequency corresponding to 20mA of
60Hz. The table below shows auxiliary frequency A as 24Hz(=60[Hz] X {(10.4[mA]-4[mA])/(20[mA] -
4[mA])} or 40%(=100[%] X {(10.4[mA] - 4[mA])/(20[mA] - 4[mA])}.
Calculating final command frequency**
30Hz(M)+(50%(G)x24Hz(A))=42Hz
30Hz(M)x(50%(G)x40%(A))=6Hz
30Hz(M)/(50%(G)x40%(A))=150Hz
M[Hz]+{M[Hz]*(G[%]*A[%])}
30Hz(M)+{30[Hz]x(50%(G)x40%(A))}=36Hz
M[Hz]+G[%]*2*(A[%]-50[%])[Hz]
30Hz(M)+50%(G)x2x(40%(A)–50%)x60Hz=24Hz
M[HZ]*{G[%]*2*(A[%]-50[%])
30Hz(M)x{50%(G)x2x(40%(A)–50%)} = -3Hz(Reverse)
M[HZ]/{G[%]*2*(A[%]-50[%])}
30Hz(M)/{50%(G)x2x(60%–40%)} = -300Hz(Reverse)
M[HZ]+M[HZ]*G[%]*2*(A[%]-50[%])
30Hz(M)+30Hz(M)x50%(G)x2x (40%(A)–50%)=27Hz
* M: main frequency reference (Hz or rpm)/G: auxiliary reference gain (%)/A: auxiliary frequency
reference Hz or rpm) or gain (%).
**If the frequency setting is changed to rpm, it is converted to rpm instead of Hz.
Auxiliary Reference Operation Ex #3
V1 is Main Frequency and I2 is Auxiliary Frequency
• Main frequency: V1 (frequency command setting to 5V and is set to 30Hz)
• Maximum frequency setting (dr.20): 400Hz
• Auxiliary frequency (bA.01): I2[Display by percentage (%) or auxiliary frequency (Hz) depending
on the operation setting condition]
• Auxiliary reference gain (bA.03): 50%
• In.01–32: Factory default
Example: an input current of 10.4mA is applied to I2, with the frequency corresponding to 20mA of
60Hz. The table below shows auxiliary frequency Aas 24Hz(=60[Hz]x{(10.4[mA]-4[mA])/(20[mA]-