Learning Advanced Features
CNF*
42 Multi-function key settings Multi Key Sel 3
- -
45
Delete all user registered
codes
UserGrp AllDel 0 No - -
* Available on LCD keypad only.
User Group Setting Details
CNF-42 Multi-Key Sel
Select 3(UserGrp SelKey) from the multi-function key setting options. If user
group parameters are not registered, setting the multi-function key to the
user group select key (UserGrp SelKey) will not display user group (USR Grp)
item on the Keypad.
Follow the procedures below to register parameters to a user group.
Set CNF- 42 to 3(UserGrp SelKey). A icon will be displayed at
the top of the LCD display.
In the parameter mode (PAR Mode), move to the parameter you
need to register and press the [MULTI] key. For example, if the
[MULTI] key is pressed in the frequency reference in DRV 01 (Cmd
Frequency), the screen below will be displayed.
❶ Group name and code number of the parameter
❷ Name of the parameter
❸ Code number to be used in the user group. Pressing the
[PROG/ENT] key on the code number (40 Code) will register
DRV-01 as code 40 in the user group.
❹ Existing parameter registered as the user group code 40
Setting range of the user group code. Entering 0 cancels the
settings.
Set a code number (❸) to use to register the parameter in the
user group. Select code number and press [PROG/ENT] key.