EasyManua.ls Logo

LSIS LSLV-S100 - Page 369

LSIS LSLV-S100
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specification
355
3 Phase 200V (5.5-15 kW)
Model
□□□□
S1002
□□□□□
0055
0075
0110
0150
Applied
motor
Heavy load
HP 7.5 10 15 20
kW 5.5 7.5 11 15
Normal load
HP 10 15 20 25
kW 7.5 11 15 18.5
Rated
output
Rated
capacity (kVA)
Heavy
load
9.1
12.2
17.5
22.9
Normal
load
11.4
15.2
21.3
26.3
Rated current
[3-Phase
input] (A)
Heavy
load
24.0
32.0
46.0
60.0
Normal
load
30.0
40.0
56.0
69.0
Rated current
[Single-Phase
input] (A)
Heavy
load
13.0
18.0
26.0
33.0
Normal
load
16.0
22.0
31.0
38.0
Output frequency
0-400 Hz (IM Sensorless : 0-120 Hz)
Output voltage (V)
3 phase 200-240V
Rated
input
Working voltage (V)
3 phase 200-240VAC (-15% to +10%)
Single phase 240VAC(-5% to +10%)
Input frequency
50-60 Hz (
±
5%)
(In case of single phase input, input frequency is only
60Hz(±5%).)
Rated current
(A)
Heavy
load
25.8
34.9
50.8
66.7
Normal
load
32.7
44.2
62.3
77.2
Weight (lb /kg)
(Non EMC Filter type)
7.3/3.3
(6.8/3.1)
7.3/3.3
(6.8/3.1)
10/4.6
(9.7/4.4)
16/7.1
(15.2/6.9)
The standard motor capacity is based on a standard 4-pole motor
The standard used for 200 V inverters is based on a 220 V supply voltage, and for 400V
inverters is based on a 440 V supply voltage.
The rated output current is limited based on the carrier frequency set at Cn.04.