HYDRAULIC AND AIR SYSTEMS 2250 SERVICE/MAINTENANCE MANUAL
2-42
Published 11-06-15, Control # 040-13
AIR PRESSURE SAFETY SWITCHES
MAINTENANCE
General
See Figure 2-43 for the following procedure.
The air pressure safety switch consists of an electric limit
switch and a diaphragm-type valve. The pressure switch is
used to control operation of auxiliary electrical devices or
circuits in response to air pressure.
Air pressure safety switches are used for the following crane
functions:
1. To monitor load drum clutch/brake maximum air
pressure to ensure the appropriate clutch/brake is
applied before allowing operation of load drums. This
switch also alerts the programmable crane controller if
the clutch/brake has not applied for a duration of 4
seconds or more. The “Air Drum Valves” fault will appear
on the crane display. Each drum clutch/brake safety
switch is N.C. (normally closed) with a trip point of 60 psi
(4,14 bar).
2. To monitor free-fall interlock treadle valve minimum air
pressure. When the selected drum’s service brake
treadle valve is locked down, the safety pressure switch
sends a signal to the programmable crane controller
allowing the operator to confirm the selected drum into
free-fall mode. Each free-fall interlock safety switch is
N.O. (normally open) with a trip point of 60 psi (4,14 bar).
3. To monitor system air pressure. The safety pressure
switch sends a signal to the programmable crane
controller to alert the operator with a “Low Air Pressure”
system fault when activated. The air pressure safety
switch is N.O. with a trip point of 90 psi (6,21 bar).
NOTE: Always confirm by crane serial number the specific
pressure at which the limit switch is set and the
operation for which the limit switch is wired by
referring to the corresponding assembly drawing
and air/electrical schematics.
Operation
As pressure increases, the diaphragm moves up causing the
adjusting screw to move up. When pressure reaches the
specified point, the adjusting screw pushes the limit switch
plunger in, and switch contacts either open or close.
If the limit switch is wired N.O., the contacts close to turn ON
the corresponding circuit when the specified pressure is
reached. If the limit switch is wired N.C., the contacts open to
turn OFF the corresponding circuit when the specified
pressure is reached.
Adjustment Requirements
Adjustment can be performed either installed on the crane or
when removed from the crane. Adjustment will be easier and
more accurate when done with the pressure switch removed
from the crane. The following items will be required to
perform the adjustment:
1. Air supply capable of being regulated up to 120 psi (8,27
bar)
2. Calibrated 0-150 psi (0-10,34 bar) air gauge
3. D.C. voltage power supply
4. Bulb-type continuity tester
5. 1/4” open end wrench
NOTE: Air pressure and electric current from the crane
source can be used for this adjustment.

Table of Contents

Other manuals for Manitowoc 2250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 2250 and is the answer not in the manual?

Manitowoc 2250 Specifications

General IconGeneral
BrandManitowoc
Model2250
CategoryConstruction Equipment
LanguageEnglish

Related product manuals