megger.com 51
7 — Setting up Fixtures, Test Accessories, and Lead
Connections
Overview of Leads, Fixtures, and Accessories Used in Testing
The following table provides an overview of the test leads or fixture used for each tester
configuration running each specific test type:
Table 2. Leads or fixtures used during testing.
Tester
Configuration
Test Type Fixture, Accessory,
or Test Leads Used
DX Host Resistance, inductance,
capacitance.
Low-voltage RLC tester leads.
DX Host DC tests. High-voltage tester leads.
DX Host Surge testing in three-phase coil
mode.
High-voltage tester leads.
DX Host Surge testing in single-coil mode.
High-voltage tester leads; leads 1
and 2 only.
DX Host Low-voltage armature or coil tests.
Low-voltage test probes (83004)
connected to RLC connector or
low-voltage RLC tester leads.
DX Host Rotor influence check (RIC) test. Low-voltage RLC tester leads.
DX Host Armature span testing. ATF-4000 fixture.
Power Packs DC tests; only HiPot and Surge run
from Power Packs. Surge testing in
three-phase mode.
High-voltage power pack leads.
PP40 leads require manual
configuration for three-phase
testing.
Power Packs Surge testing in single-coil mode.
High-voltage power pack leads.
Leads 1 and 2 only for three-phase
leads.
Power Pack
(PP85 only) or
AT101-ZTX
Low-impedance armature testing. ATF-5000 fixture or
ATP02-P probes.
Power Pack
(PP85 only) or
AT101-ZTX
Low-impedance single-coil testing. ATP02-P probes or
ATP02-C clips.

Table of Contents