The Tool Settings - contd.
Function Description Limits
Shutdown
Temperature
Sets the temperature to which each Shutdown group
must fall before the next group is switched off.
Raising the shutdown Temperature means that zones
do not have to cool down so much until subsequent
stages are switched off which shortens the overall
shutdown time. Lowering the Shutdown Temperature
has the opposite effect and lengthens the shutdown
time.
The Shutdown
Temperature setting
defaults to “0” which
represents an extremely
long shutdown interval.
The highest shutdown
temperature permitted
is 260° C or 500°F and
if this set value is equal
to, or higher than, the
normal temperature,
then it has no effect and
the shutdown interval
becomes dependant on the
Shutdown timer.
Temperature
Scale
Choose [
Degree C] or [Degree F] as required.
Weight Unit
Choose Metric [
Kg] or Imperial [Lbs] as the unit for
weight.
Finished changing Tool Settings?
If you have made any changes to Tool settings note that it takes two steps to save them.
First, you must choose [
Accept] on this screen and then go to the ToolStore page and
choose [
Save].