SETUP
© 2014 Mold-Masters (2007) Limited. All Rights Reserved.
Revised 1 Oct, 2014
5-20
www.moldmasters.com
The System Settings - contd.
Function Description Limits
Supply Voltage Enter the System Supply Voltage; It is used to
calculate the “Watts” display. This is normally the
phase-neutral voltage on a star supply and the
phase-phase voltage on a delta supply.
Maximum supplied
Voltage is 400V.
Temperature Precision Allows you to set the resolution for the Actual
temperature seen on the Display Page to a oating
point scale which displays temperature to within one
tenth of a degree or an integer scale which rounds
the displayed temperature to the nearest whole
degree. Select [
Float] or [Integer] as appropriate.