Item
No.
Item Input Data Description Default Related
Program
42 Incoming Off-
Hook Ring Setup
0=Speaker Off-Hook
Ring
1=Headset Off-Hook
Ring
0 11-11-37
11-11-62
15-02-12
15-02-41
43 Headset Ring
Duration
0=No Switch to Speak-
er Ring
1=10 sec
2=20 sec
3=30 sec
4=40 sec
5=50 sec
6=1 minute
0 11-11-62
15-02-41
15-02-42
46 Backlight LCD
duration
0 = Continuous on
1 = 5 seconds
2 = 10 seconds
3 = 15 seconds
4 = 30 seconds
5 = 60 seconds
Set how long the Backlight LCD
stays on.
2
48 Short Ring Setup 0 = Disable
1 = Enable
0 80-09-01
80-09-02
80-09-03
50 Mute Lamp Sta-
tus Change
0 = normal
1 = Lamp Status
Change
0
54 Menu Operation
Mode
0 = Automatic Close
1 = Manual Close
0
55 VRS Message
Number
0 ~ 100 0
56 Screen Saver
Timer (SL1000)
0 ~ 200 (0 ~ 2000 sec-
onds)
0
57 Caller Log on
busy
0 = Off
1 = On
0 15-02-34
58 Display mode of
trunk incoming
(V1.5 Deleted)
0 = Caller ID
1 = Memo Information
0 13-04-08
13-04-09
13-04-10
60 Soft Key/Naviga-
tion key Mode
0 = Standard Mode
1 = Advanced Mode1
2 = Advanced Mode2
1
61 Backlight Max
Brightness
0 ~ 8 6
62 Backlight Min
Brightness
0 ~ 8 0
63 Auto Backlight 0 = Off
1 = On
0 15-02-64
64 Auto Backlight
bound threshold
(auto setting)
0 ~ 13 13 15-02-63
65 Auto Backlight
bound threshold
(manual setting)
0 ~ 13 0
66 Dial Button
Backlight
0 = Off
1 = On
1
67 Caller ID shared
groups
0 = Personal
1 ~ 8 = Shared Group
0 20-49-01
68 Mode setting for
incoming call
from extension
Read Only:
0 = Voice
1 = Signal
This program can only be
change by using PC Program-
ming.
1
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-135
Program
15

Table of Contents

Other manuals for NEC SL 1000

Related product manuals