For PRIU PKG Setup
ISDN Line Number 01 ~ 30
Item No. Item Input Data Description Default
01 ISDN Line Mode 0 = No setting
1 = T-Point
2 = S-Point
6 = S-Point (Leased Line)
1
02 Logical Port Number [0 : No setting] = 0
[1 : T-Point] = 1 ~ 126 (SL1000) 1 ~ 96
(SL1100)
[2 : S-Point] = 1 ~ 128 (SL1000) 1 ~
120 (SL1100)
[6 : S-Point (Leased Line)] = 1 ~ 128
(SL1000) 1 ~ 120 (SL1100)
The start port num-
ber of a PRI line is
displayed.
0
03 CRC Multi-frame (CRC4)
(Only for 2M = 30ch Mode)
0 = off
1 = on
1
04 Layer 3 Timer Type 1 ~ 5
Each timer value of
Layer 3 is set up for
each type in Program
81-06 (T-Bus)
1
05 CLIP Information 0 = No
1 = Yes
Based on this setting, the
system includes a Pre-
sentation Allowed (1) or
Presentation Restricted
(0) in the Setup message
to allow or deny the Call-
ing Party Number. Pro-
gram 15-01-04 must also
be set to 1 if this option is
enabled.
1
06 Length of Cable 0 = Level 1
1 = Level 2
2 = Level 3
3 = Level 4
4 = Level 5
2
07 S-point DDI digits 0 - 4 0
08 Dial Sending Mode 0 = Enbloc Sending
1 = Overlap Sending
ISDN Protocol definition 1
09 Dial Information Element 0 = Keypad Facility
1 = Called Party Number
ISDN Protocol definition
Only when Dial Sending
Mode (10-03-08) is set for
1 (Overlap Sending).
1
13 Loss-Of-Signal Detection
Limit
0 = Level 0 (lowest sensitivity)
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
5 = Level 5
6 = Level 6
7 = Level 7 (highest sensitivity)
If the transmit/receive
voltage is less than the
setting in 10-03-13, the
system considers this as
Loss-Of-Signal and the
PRI does not come up.
Note that there are differ-
ent values based on the
setting in 10-03-12 for the
PRI.
2
14 Service Protocol for S-point 0 = Keypad facility
1 = Specified Protocol for Aspire sys-
tem
0
15 Call Busy Mode for S-point 0 = Alerting
1 = Disconnect
0
16 Two B-Channel Transfer for
PRI Service
0 = off
1 = on
0
ISSUE 3.01 SL1000/SL1100