EasyManuals Logo

Omron NS Programming Manual

Omron NS
683 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #227 background imageLoading...
Page #227 background image
Section 2 NS Series Functions 2-11 Multifunction Objects
2-180
NS Series Programming Manual
Set Value
The Set Value action sets the write address to a set value.
1
2
3
No. Item Details
1 Set Value Sets a set value to be written to the write address.
When indirect specification is selected, the contents of the set address are written.
2 Maximum
Limit
Sets the maximum limit. Either a fixed value or indirect specification can be selected.
3 Minimum
Limit
Sets the minimum limit. Either a fixed value or indirect specification can be selected.
Increment/Decrement
When the button is pressed, the contents of the address are incremented or decremented and set.
1
2
3

Table of Contents

Other manuals for Omron NS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NS and is the answer not in the manual?

Omron NS Specifications

General IconGeneral
Power Supply24 VDC
Display Size5.7 to 12.1 inches (depending on the model)
Resolution320 x 240 to 800 x 600
Touchscreen TypeResistive
Display TypeTFT LCD
Communication InterfacesRS-232C, RS-422/485, Ethernet, USB
MemoryFlash memory
Operating Temperature0 to 50°C (depending on the model)
Storage Temperature-20°C to 60°C
Protection RatingIP65 (front panel)
DimensionsVaries depending on the model
WeightVaries depending on the model
CPUProprietary Omron CPU (performance varies depending on the model)