6-79
Function(s) Setting(s) Page
3-Wire Control (with forward/reverse rotation input) 0 5-16
Multi-step References 1 through 3 and Jog Reference 3 through 6 5-17
Multi-Accel/Decel 1 and 2 (acceleration/deceleration time selectors 1 and 2) 7 and 1A 5-18
Fast-Stop (Emergency stop) 15 and 17 5-19
Forward and Reverse Jog commands 12 and 13 5-19
Terminal 13/14 Switch 1F 5-19
Timer Function Input 18 6-46
Energy-saving operation 63 6-13,
6-37
Two-motor switching control 16 6-67
PID control integral reset 30 6-54
PID control integral hold 31 6-54
D Local/Remote Selection (Setting: 1)
OFF Operate with the frequency reference and run command specified in b1-01 (the frequency
reference source selector) and b1-02 (the run command source selector).
ON Operate with the frequency reference and run command set at the Digital Operator.
• With
this setting, the multi-function input selects the input method for
the frequency reference and run
command.
• The input method can be switched only when the Inverter is stopped.
• The
Digital Operator
’
s LOCAL/REMOTE Key is disabled when this function has
been set in a multi-
function input.
Note 1. There
is no dif
ference between two modes if the parameters
b1-01 and b1-02 are both set to
0.
Note 2. The
above values are set through the Digital Operator and the
frequencies are stored in fre
-
quency references 1 through 8 (d1-01 through d1-08) or the inching frequency reference
(d1-09) in remote or local mode.
Note 3. Multi-function
inputs 1 through 6 are enabled in remote or local
mode. The stop command is,
however, disabled in local mode only if the 3-wire sequential set value is 0.
Note 4. If
the run command is input
when switching the Inverter to remote mode from local mode, the
run
input will be ignored to ensure safety
. T
urn the run command OFF once. Then
turn the run
command
ON again in remote mode. If the parameter b1-07
(LOC/REM RUN Sel) is set to 1,
the
run command will not be ignored.
In this case, the Inverter may operate immediately when
switched to remote mode from local mode. Take necessary measures for safety.
D Option/Inverter Selection (Setting: 2)
OFF The Inverter’s frequency reference is enabled.
ON The Optional Card’s frequency reference is enabled.
• With
this setting, the multi-function input enables the frequency reference input from the Inverter itself
or the one from Optional Card.
• The frequency reference input can be switched only when the Inverter is stopped.
• Be
sure that b1-01 (the frequency reference source selector) has been set to 0 (Operator)
or 1 (exter
-
nal
terminal). Only the frequency reference from the Optional Card will be enabled if b1-01 is set to 3
(Option PCB).
Advanced Operation Chapter