7-11
H Reference Hold: b6
Para
meter
Name
Description Setting
range
Default
setting
Chan-
ges
Control
mode
Page
meter
No.
Display
name
range setting ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
b6-01
Dwell
frequency
at start
Note:
The dwell function is
used to stop/start the out
-
put frequency temporarily
h d i i t ith
0.0
to
400.0
0.0 NO A A A A 6-57
Dwell Ref
@Start
qy y
when driving a motor with
a heavy load.
Output frequency
b6-02
Dwell time
at start
Output frequency
0.0
to
10.0
0.0 NO A A A A 6-57
Dwell T
ime
@Start
b6-03
Dwell
frequency
at stop
Time
b6-02
b6-01
b6-03
b6-04
0.0
to
400.0
0.0 NO A A A A 6-57
Dwell Ref
@Stop
b6-04
Dwell time
at stop
0.0
to
10.0
0.0 NO A A A A 6-57
Dwell T
ime
@Stop
H Droop Control: b7
Para
meter
Name
Description Setting
range
Default
setting
Chan-
ges
Control
mode
Page
meter
No.
Display
name
range setting ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
b7-01
Droop
control gain
Sets the slip as a percentage of
maximum frequency when the
maximum frequency is specified
and the rated torque occurs.
0.0 to
100.0
0.0 OK X X X A 6-18
Droop gain
q
Note:
Droop-control is not per
-
formed when the setting
is 0.0.
b7-02
Droop
control
delay time
Droop control responsiveness
parameter
Note:
When hunting or vibration
0.03 to
2.00
0.05 OK X X X A 6-18
Droop
delay time
Note:
When
hunting
or
vibration
occurs, increase the val-
ue.
Parameter Lists Chapter
7