7-16
Para
meter
No.
PageControl
mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
DescriptionNamePara
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
C3-06
Selects out
-
put voltage
limit opera
-
tion
Selects the output voltage limit
function so that the voltage
calculation in open-loop vector
control does not become
saturated.
0:
Disabled. (Output voltage
saturation is not limited. Slip
compensation is disabled.)
1:
Enabled. (Output voltage
saturation is suppressed.
Speed accuracy is not
reduced.)
0, 1
0 NO X X A A 6-6
Output V
limit
reduced
.
)
Note:
Be sure that there is suf
fi-
cient output current ca
-
pacity in the inverter be
-
cause the output current
is about 10% higher when
this function is enabled.
Note: The speed accuracy may
be reduced when the in
-
put voltage is very low
.
Note When
the control
mode is changed, the Inverter reverts to default settings. (The open loop vector
control default settings are given above.)
H Torque Compensation: C4
Para
meter
Name
Description Setting
range
Default
setting
Chan-
ges
Control
mode
Page
meter
No.
Display
name
range setting ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
C4-01
Torque
compensa-
tion gain.
Sets torque compensation gain
as a ratio.
Note:
Usually setting is not nec
-
essary.
Adjust in the following cir
-
cumstances:
When the cable is long;
increase the set value.
When the motor capacity
is smaller than the capac
-
ity of the Inverter (Max.
applicable motor capac
-
ity), increase the set val
-
ues
.
0.00 to
2.50
1.00 OK B B B X 6-60
T
orq Comp
Gain
ues
.
When the motor is vibrat
-
ing, decrease the set val
-
ues.
When adjusting the gain, be
sure that the output current at
low speeds does not exceed
100% of the Inverter
s rated
output current.
Note:
Do not change the torque
compensation gain when
using open-loop vector
control.
Parameter Lists Chapter
7