7-52
Para
meter
No.
PageControl
mode
Chan-
ges
during
opera-
tion
De-
fault
setting
Set-
ting
range
DescriptionNamePara
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
con-
trol
Chan-
ges
during
opera-
tion
De-
fault
setting
Set-
ting
range
Description
Display
name
o1-02
Monitor
selection
after
power-on
Sets the monitor item to be
displayed when the power is
turned on.
1:
Frequency reference
2:
Output frequency
1 to 4
1 OK B B B B 6-111
Power-On
Monitor
3:
Output current
4:
The monitor item set for
o1-01
o1-03
Frequency
reference
setting and
display
units
Sets the units that will be set
and displayed for the
frequency reference and
frequency monitor
.
0:
0.01-Hz units
1:
0.01% units (Maximum
frequency is 100%)
2 to 39:
r/min units (Sets the
motor poles. Cannot
be set in Flex V
ector
Control.)
40 to 39999:
User desired
display
Set the desired values for
setting and
display for the
0
to
39999
0 NO B B B B 5-9
Display
Scaling
.
Example: When the max. fre
-
quency value is 200.0, set
12000
Set four digits
without the dec
-
imal point
Set the position
of the decimal
point in the first
digit.
o1-04
V/f
pattern
setting
units
Set the V/f pattern setting units.
(E1-04, 06, 09 set units)
0: Hz units
0, 1
0 NO X X X B 6-31
Display
Units
s
Note: Ef
fective only in the flux
control vector mode.
o1-05
Not used
Do not set.
--- 0 --- --- --- --- --- ---
Control
mode
Page
meter
No.
Display
name
range setting ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
o2-01
Local/Re-
mote Key
Sets the Digital Operator
Local/Remote Key
enabled/disabled.
0, 1
1 NO B B B B 6-112
Local/Re-
mote Key
1:
Enabled (Switches between
the Digital Operator and the
parameter settings.)
Parameter Lists Chapter
7