9-10
H Separately Mounted Options
D Scaling Meter
K3TJ-V11
By connecting to the Inverter’s multi-function
analog output (analog monitor), it is possible to
display the number of rotations, line speed,
and so on.
D Standard Models
Model Control power supply Display
K3TJ-V111R
100 to 200 VAC
Red LED indicator
K3TJ-V111G Green LED indicator
K3TJ-V116R
24 VDC with insulation (See note.)
Red LED indicator
K3TJ-V116G
()
Green LED indicator
Note The power supply circuit and input circuit are insulated.
D Standard Specifications
Sampling time 0.5 s
Display refresh period 0.5 s
Process value averaging method Simple average or movement average
Number of process value
averaging operations
1, 2, 4, or 8 times
Max. displayed digits 4 digits (–1,999 to +9,999)
Display 7-segment red or green LED with character height of 14.2 mm
Decimal display Selected by the Up and Down Keys and parameter selector
Scaling function Shift/Scaling adjustment is possible with the Up and Down Keys and
parameter selector
Scaling range –1,999 to +9,999
Zero-limit range 0 to 99 digits
Overflow display Flashes
Zero-suppress function Yes
External control Process value hold (by short-circuiting the rear terminals)
Enclosure rating (conforming to
IEC standards)
Front panel: IP51 (see note)
Case: IP20
Terminals: IP00
Memory protection Non-volatile memory (no backup battery required)
Note IP51
ensured when the optional K32-L49SC W
ater-resistive Soft Front
Cover is used and IP50