9-11
D Wiring Example
+
E
0 to 10 VDC
1
GND
3
SYSDRIVE
Analog
monitor
Analog output
K3TJ
R
S
T
R
S
T
U
V
W
IM
Three-phase
power supply
Circuit breaker
Inverter ’s
internal
circuitry
HOLD
56
8
9
D External Dimensions
Weight:
200 g
Panel
Cutouts (Recommended)
75 min.
120 min.
LED
Display Character Size
14.2
mm
7.8 mm
45
+0.6
–0
92
+0.8
–0
66
98
92
96
48
3.5
43
D Analog Operators
3G3IV-PJVOP96 Analog Operator (Standard Steel-plate Type)
The
3G3IV-PJVOP96
Analog Operator is a control
panel that allows frequency and run/stop operation by ana
-
log references from a distance (50 m). Frequency scale: 75 Hz, 150 Hz, 220 Hz.
Frequency meter
Main/auxiliary frequency reference switch
Error limit
Forward/stop/reverse switch
Case
Frequency setting resistor
Power supply indicator
Error indicator
Front panel
Run indicator
Frequency meter
calibration resistor
D Standard Models
Model Frequency meter specifications
3G3IV-PJVOP961 DCF-6A 3 V 1 mA 75 Hz
3G3IV-PJVOP962 DCF-6A 3 V 1 mA 150 Hz
3G3IV-PJVOP963 DCF-6A 3 V 1 mA 220 Hz
Specifications Chapter