0.4 20P7 70 W 200 Ω 1 4 220% 48
class
0.75 20P7 70 W 200 Ω 1 4 125% 48
1.5 21P5 260 W 100 Ω 1 5 125% 16
2.2 22P2 260 W 70 Ω 1 7 120% 9.6
3.7 23P7 390 W 40 Ω 1 4 125% 9.6
5.5 25P5 520 W 30 Ω 1 3 115% 9.6
7.5 27P5 780 W 20 Ω 1 2 125% 9.6
11 2011 2400 W 13.6 Ω 1 1 125% 9.6
15 2015 3000 W 10 Ω 1 1 125% 9.6
18.5 2018 4800 W 8 Ω 1 1 125% 6.4
22 2022 4800 W 6.8 Ω 1 1 125% 6.4
30 2015 3000 W 10 Ω 2 1 125% 9.6
37 2015 3000 W 10 Ω 2 1 100% 9.6
45 2022 4800 W 6.8 Ω 2 1 120% 6.4
55 2022 4800 W 6.8 Ω 2 1 100% 6.4
75 2022 4800 W 6.8 Ω 3 1 110% 6.4
400-V
0.4 40P7 70 W 750 Ω 1 11 230% 64
class
0.75 40P7 70 W 750 Ω 1 11 130% 64
1.5 41P5 260 W 400 Ω 1 6 125% 64
2.2 42P2 260 W 250 Ω 1 7 135% 32
3.7 43P7 390 W 150 Ω 1 4 135% 32
5.5 45P5 520 W 100 Ω 1 3 135% 32
7.5 47P5 780 W 75 Ω 1 2 130% 32
11 4011 1040 W 50 Ω 1 2 135% 20
15 4015 1560 W 40 Ω 1 2 125% 20
18.5 4018 4800 W 32 Ω 1 1 125% 19.2
22 4022 4800 W 27.2 Ω 1 1 125% 19.2
30 4030 6000 W 20 Ω 1 1 125% 19.2
37 4037 9600 W 16 Ω 1 1 125% 12.8
45 4045 9600 W 13.6 Ω 1 1 125% 12.8
55 4030 6000 W 20 Ω 2 1 135% 19.2
75 4045 9600 W 13.6 Ω 2 1 145% 12.8
110 4030 6000 W 20 Ω 3 1 100% 19.2
160 4045 9600 W 13.6 Ω 4 1 140% 12.8
185 4045 9600 W 13.6 Ω 4 1 120% 12.8
220 4045 9600 W 13.6 Ω 5 1 125% 12.8
300 4045 9600 W 13.6 Ω 6 1 110% 12.8
Note 1. The
Connectable
column indicates the maximum number of Braking Resistor
Units that can
be connected to a single Inverter or Braking Unit.
Note 2. Do
not use a resistor with a resistance of less than
the minimum connection resistance shown
above. Otherwise, the Inverter or Braking Unit will be damaged.
Specifications Chapter