9-17
D Braking Resistor (Yaskawa Electric)
3G3IV-PERF150WJ
The
3G3IV
-PERF150WJ
shortens deceleration time by consuming the motor
’
s regenerative energy
by means of a resistor. (Usage rate: 3% ED)
Note The
“usage rate: 3% ED” means that 3% of the operation time in one cycle can be used for braking
(deceleration).
D Standard Models
Inverter Braking Resistor
Approx.
braking torque
(3% ED)
200-V class
0.4 201 150 W 200 Ω 1 220%
0.75 201 150 W 200 Ω 1 125%
1.5 101 150 W 100 Ω 1 125%
2.2 700 150 W 70 Ω 1 120%
3.7 620 150 W 62 Ω 1 100%
400-V class
0.4 751 150 W 750 Ω 1 230%
0.75 751 150 W 750 Ω 1 130%
1.5 401 150 W 400 Ω 1 125%
2.2 301 150 W 300 Ω 1 115%
3.7 201 150 W 200 Ω 1 110%
(See note.)
Note Usage rate: 2%.
D External Dimensions (mm)
Specifications Chapter