2-42
D 3G3FV-PPGX2 (For Flux Vector Control Mode Only)
Terminal No. Contents Specifications
TA1
1
Power supply for pulse generator
12 VDC (±5%), 200 mA max. (see note)
2
0 VDC (GND for power supply)
3 5 VDC (±5%), 200 mA max. (see note)
4 A-phase + input terminal
Line driver input (RS-422 level input)
5 A-phase – input terminal
Maximum response frequency: 300 kHz
6 B-phase + input terminal
7 B-phase – input terminal
8 Z-phase + input terminal
9 Z-phase – input terminal
10 Common terminal 0 VDC (GND for power supply)
TA2
1 A-phase + output terminal
Line driver output (RS-422 level output)
2 A-phase – output terminal
3 B-phase + output terminal
4 B-phase – output terminal
5 Z-phase + output terminal
6 Z-phase – output terminal
7 Control circuit common Control circuit GND
TA3 (E) ---
Note 5 VDC and 12 VDC cannot be used at the same time.