263
DP-2330/3030
MAR 2005
Ver. 2.1
DP-2310/3010
7.2. Unpacking
Visually check the condition and contents of the box for completeness or any shipping damage before
installation.
Remove all filament tapes used to secure the Fuser and Process Units during shipment.
Caution:
The machine weights approximately 181 lb (82 kg) with the i-ADF pre-installed. To prevent injuries, use
the appropriate number of personnel and the proper equipment to lift or move the machine.
7.3. Installation Procedure
Note:
1. Refer to each individual Installation Instructions when installing Stands or other Options.
2. The following machine illustrations, depict a DP-3010 with the USA/Canadian standard configuration.
3. The scanner is held in place by a Shipping Blue Screw to prevent damage during transit.
Do Not turn the Power Switches ON before unlocking the scanner.
4. The machine is shipped from the factory with the Pressure Roller locked in the opened position to
avoid the possibility of damaging the Pressure Roller.
Do Not turn the Power Switches ON before unlocking the Pressure Roller.
7.3.1. Installation Procedure
(1) Pull out to lock the Left Front Handle in place.
Note:
To release the Handle, push the Release Latch
toward the machine and push the Handle into the
machine.