277
DP-2330/3030
MAR 2005
Ver. 2.1
DP-2310/3010
8.2. Service Notes "Firmware Update" for PCL or PS Option Installation
(For DP-2310/3010)
To u s e PCL (DA-PC300) or PS (DA-MC300) option individually or in combination with other options,
changing to Type B or Type D SC firmware is required. The required firmware is on the CD included with
the options.
Note:
The DA-EM600 must be installed for the printer controllers above to function. The only time a DA-EM600
is needed is if you are installing the PostScript (PS) or PCL option. There will never be a need for 2 of
these, even if there are other options, such as Fax, added.
Before proceeding, it is important to determine the Final Configuration of your machine in order to correctly
identify the required firmware from the table below. Carefully read and follow the Installation Instructions for
the appropriate option.
The firmware for SC, SPC and PNL must be updated in this sequence as a set. Please update the firmware
with the latest version as a set by referring to the following table.
Firmware Version Table (For DP-2310/3010)
Standard Firmware
(SC = Type A)
PCL Firmware
(SC = Type B)
PostScript Firmware
(SC = Type D)
SC DP-SFDL2AxVxxxxx_xx DP-SFDL2BxVxxxxx_xx DP-SFDL2DxVxxxxx_xx
PNL SFDL2PNLAxVxxxxx_xx
←←
SPC SFDL2SPCAxVxxxxx
←←
Slot 1 FROM PCB Not Required Required Required