Users Manual of WGSW-20160HP/WGSW-24040HP series
467
LLDP Hold
Description:
Set or show LLDP Tx hold value.
Syntax:
LLDP Hold [<hold>]
Parameters:
<hold>: LLDP hold value (2-10)
Default Setting:
3
LLDP Delay
Description:
Set or show LLDP Tx delay.
Syntax:
LLDP Delay [<delay>]
Parameters:
<delay>: LLDP transmission delay (1-8192)
Default Setting:
2
LLDP Reinit
Description:
Set or show LLDP reinit delay.
Syntax:
LLDP Reinit [<reinit>]
Parameters:
<reinit>: LLDP reinit delay (1-10)
Default Setting:
2