Standardized Error Codes
The system generates error codes and stores those codes in a block of memory known as the
ERROR LOG, and does so when it detects conditions that are defined in the error reporting
software.
The error log has 10 locations in a first in-first out configuration. In other words it will display the
10 MOST RESENT errors, with error location 1 being the most recent. While not all system issues
will generate an error code, those that do are shown here. These codes are useful in isolating
certain system issues.
To view errors in the error log, press and hold the reset key for at least 6 seconds. If there are
errors logged, this action will take you into the error log. The error log can also be accessed through
the “Information Display” by pressing either pause or reset, then the numbers 6, 5.
The following is a list of the error codes currently assigned to the AMT12:
Error 05 Key depressed at power up
Error 09 Memory error (Lower PCA)
Error 12 Watchdog (Lower PCA)
Error 30 Upper PCA not receiving data from lower PCA
Error 31 Faulty data received from lower PCA
Error 32 Lower PCA not receiving data from upper PCA
Error 33 Faulty data received from upper PCA
Error 37 ESTOP Not Working
Error 40 No lift motion detected
Error 42 Lift position value out of range
Error 44 Un-commanded lift movement