EasyManuals Logo

Precor AMT12 base User Manual

Precor AMT12 base
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 36
Description
The power up test sequence has detected a key in the operated condition (Stuck Key). The power up test
sequence is performed every time the unit is turned on (powered up). This test is performed because a
permanently stuck key will inhibit the correct operation of the unit.
Possible Causes
1 A key on the display housing is permanently stuck in the operated condition.
2 One of the upper PCA’s keypad interface chips has failed.
3 Liquid (perhaps perspiration) is present on the surface of the display overlay.
Possible Remedies
1 Remove the keypad connector cable from the upper PCA. Restart the power up sequence; if the
ERROR 5 (Stuck Key) is no longer present, the keypad is the cause. The keypad is typically part of
the display housing. Replace the display housing to correct the problem.
2 Remove the keypad connector cable from the upper PCA. Restart the power up sequence; if the
ERROR 5 (Stuck Key) is still present, the upper PCA is the cause. Replace the upper PCA to correct
this problem.
3 Wipe the surface of the display overlay clean of all liquid. Restart the power up sequence; if the
ERROR 5 (Stuck Key) is no longer present, the liquid was the cause.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor AMT12 base and is the answer not in the manual?

Precor AMT12 base Specifications

General IconGeneral
BrandPrecor
ModelAMT12 base
CategoryFitness Equipment
LanguageEnglish

Related product manuals