Section 23: ACCESSORIES
PA1562
19
6.8.2 Fresh Water Tank Filling
Connect the fresh water supply hose to the fresh
water reservoir fill connection (Fig. 25) located in
the curb-side section of engine compartment.
Fill the reservoir until the overflow tube leaks,
signaling that the reservoir is full.
DANGER
Never put antifreeze in fresh water tank;
antifreeze is toxic.
WARNING
If tank has not been drained for an extended
period of time, draining and filling operations
must be repeated three (3) times in order to
clean tank and eliminate contaminated water.
6.9 LIQUID SOAP DISPENSER
A liquid soap dispenser may have been installed
as optional equipment. To refill dispenser,
proceed as follows:
1. Turn cover slightly clockwise until it stops.
2. Lift out piston and spout, cover and supply
tube.
FIGURE 27: LIQUID SOAP DISPENSER 23039
3. Fill dispenser with soap. This model can
dispense vegetable oil soaps, synthetic
detergents, and lotion soaps.
CAUTION
Never use abrasive cleaners.
4. Replace supply tube, piston, and spout
mechanism reversing the steps above.
5. Secure the cover by turning clockwise until
lock snaps into position.
NOTE
The dispenser requires priming when
extremely viscous lotion soaps are used.
Remove piston and spout, cover and supply
tube assembly. Pump water into assembly,
then replace into dispenser.
6.10 FLUSH PUSH-BUTTON
The green flush push-button is located near the
toilet. Press on push-button to actuate a
pneumatic timer located on the other side of wall.
This timer allows an electric current flow during a
preset time to a pump into the sump tank.
6.10.1 Pneumatic Timer Removal and
Installation
1. Unscrew and remove the flush push-button
locking ring.
2. Remove steel plate located on L.H. side of
pushbutton switch.
3. Remove pneumatic timer through this
opening, taking care to disconnect electric
wires.
NOTE
Care must be taken to avoid losing the
spacers installed on the mounting sleeve.
4. Reverse the above procedure to reinstall
timer. The recommended torque for the lock
nut is 15 Lbf-ft· (21 Nm).
6.10.2 Timer Adjustment
Timer can be adjusted from 0.2 second to 3
minutes by turning the time adjustment screw
clockwise to increase time, and counterclockwise
to decrease time. To gain access to the time
adjustment screw, repeat steps 1, 2 and 3 in the
previous paragraph "6.10.1 Pneumatic Timer
Removal and Installation".