Tools Required
Press
11/16" and 7/8" Deep well sockets
Needle Bearing Removal
1. Place the cover in a press with the flange side
down. Press the needle bearing (22) out of the
cover.
Press out needle
bearing
Press
11/16" Socket
or other
suitable tool
2. Make sure all needles roll freely in the needle
bearing (22).
Inspect needle
bearing
3. Put the cover in a clean press with the flange side
up. Press the needle bearing (22) into the cover,
lettered side toward the pressing tool, until flush
with the inside surface.
Press in needle
bearing
Press
7/8" Deep well
socket, or
other suitable
tool
Make sure the press is clean and
free of debris so as not to damage
the face of the cover on which the bottom plate rests. If
damage occurs the cover will have to be replaced for
the pump to function properly.
CAUTION
!