MANUAL NUMBER 160339
REVISION 09SEPT04 PAGE 9
MANUAL ACTIVATION SWITCH
The Manual Activation Switch allows immediate system activation (extinguisher
discharge and engine shutdown) by the vehicle operator at any time. Activation of the switch is
accomplished by twisting and pulling the tamper seal (not shown) to remove, lifting the cover
and pressing the red “FIRE” button for more than half a second. After the Manual Activation
Switch has been activated, the Protection Panel will blink the fire “ALARM” indicator until power
has been cycled to the system.
FIGURE 6 – MANUAL ACTIVATION SWITCH (DEPICTED WITHOUT TAMPER SEAL)
CONE NOZZLE
The Cone Nozzle is constructed of plated steel and contains a 45° steel cone, causing
the nozzle to disperse a cone shaped spray of dry chemical. The nozzle has a silicone rubber
protective cap that is blown off by the dry chemical discharge.
FIGURE 7 – CONE NOZZLE