EasyManuals Logo

PREVOST X3-45 Multiplex User Manual

PREVOST X3-45 Multiplex
1422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #264 background imageLoading...
Page #264 background image
FAULT CODE MANUAL Created on 00-04-25 15:30
- 12 -
MID (P)PID/SID FMI Seriousness Component/Function Display text
136 SID 14 4 Diag. 1 Voltage, low voltage/open
circuit
Valve relay
136 SID 14 5 Ground diagonal, open circuit Valve relay
136 SID 14 5 ECU-Ground or WL-Ground Valve relay
136 SID 14 6 Ground diagonal 1, shorted to low Valve relay
136 SID 14 7 Voltage feeding solenoid valve
ABS
Valve relay
136 SID 15 3 Voltage feeding solenoid valve
ABS
Valve relay
136 SID 15 4 Voltage feeding solenoid valve
ABS
Valve relay
136 SID 15 5 Voltage feeding solenoid valve
ABS
Valve relay
136 SID 15 6 Voltage feeding solenoid valve
ABS
Valve relay
136 SID 15 7 Valve relay diagonal 2 Valve relay
136 SID 18 3 Diff. Brake Valve, shorted to
UBATT
ATC valve L
136 SID 18 5 Diff. Brake Valve, open circuit ATC valve L
136 SID 18 6 Diff. Brake Valve, shorted to
ground
ATC valve L
136 SID 19 3 Diff, lock shorted to UBATT ATC valve R
136 SID 19 5 Diff, lock open circuit ATC valve R
136 SID 19 6 Diff, lock shorted to ground ATC valve R
136 SID 23 5 Warning lamp ABS Warning light bulb
136 SID 231 5 SAE J1939 Control link SAE J1939 data link
136 SID 231 6 SAE J1939 Control link SAE J1939 data link
136 SID 231 9 SAE J1939 Control link SAE J1939 data link
136 SID 231 12 SAE J1939 Control link SAE J1939 data link
136 SID 248 2 CAN plausibility -
136 SID 248 5 CAN open circuit -
136 SID 248 6 CAN grounded circuit -
136 SID 248 9 CAN time-out -
136 SID 248 12 CAN, internal error -
136 SID 249 5 SAE-J1922 datalink open circuit -
136 SID 249 6 SAE-J1922 datalink grounded
circuit
-
136 SID 249 10 SAE-J1922 bus not free -
136 SID 251 3 Overvoltage Diag. 1 or 2 Power supply
136 SID 253 1 ASR Configuration Calibration memory
136 SID 253 2 ABS Configuration Calibration memory
136 SID 253 2 EEPROM Wheel parameter
incorrect
Calibration memory
136 SID 253 12 EEPROM Checksum Calibration memory
136 SID 254 2 Internal Error Controller #1
136 SID 254 5 ABS (ASR) ELECTRONIC no
loads
Controller #1
136 SID 254 8 Excessive slip / dynotester Controller #1
136 SID 254 9 Modulator-Valve activation-time Controller #1
136 SID 254 12 Internal Error Controller #1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST X3-45 Multiplex and is the answer not in the manual?

PREVOST X3-45 Multiplex Specifications

General IconGeneral
Length45 ft
Width102 in
EngineVolvo D13
Horsepower500 hp
GVWR54, 000 lbs
Height146 in
Sleeping CapacityVaries based on floor plan
Water CapacityVaries based on floor plan

Related product manuals