Pressing q while in “Coupling targets” screen reveals the context menu shown
below.
The displayed menu items perform the following functions:
Reset all values – used to clear all entered coupling target values and to reset
coupling format and dimension back to those used in the “Set-up” screen
Recalculate targets – used to set coupling target values to correspond to the
coupling diameter used in the “Set-up” screen
Sign convention – displays the definition and graphic depiction of sign
convention
Left/Right/Both – used to select the direction considered when analyzing
coupling targets. If the option “Both” is selected, coupling target values
cannot be edited
Dial gauge values – used to enter coupling target values as dial indicator
readings
Thermal growth – used to access the machine thermal growth screen
The displayed context menu
items can be accessed
directly by pressing the
corresponding data entry
key.