Remote Commands in the Receiver Application
R&S
®
ESW
543User Manual 1177.6298.02 ─ 08
15.7.4.3 Marker Search
Commands to configure a marker search described elsewhere.
CALCulate<n>:MARKer<m>:PEXCursion on page 463
CALCulate<n>:MARKer<m>:COUPled[:STATe].................................................................543
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe].................................................................543
CALCulate<n>:MARKer<m>:X:SLIMits:LEFT....................................................................544
CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt...................................................................544
CALCulate<n>:THReshold..............................................................................................544
CALCulate<n>:THReshold:STATe....................................................................................545
CALCulate<n>:MARKer<m>:COUPled[:STATe] <State>
This command couples or decouples the receiver frequency to the current marker fre-
quency.
Suffix:
<n>
.
Marker
<m> irrelevant
Parameters:
<State> ON | OFF | 1 | 0
*RST: OFF
Example: //Couples receiver frequency to marker frequency
CALC:MARK:COUP ON
Manual operation: See "Synchronizing the receiver frequency to the marker fre-
quency" on page 179
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe] <State>
This command turns marker search limits on and off for all markers in all windows.
Suffix:
<n>
.
irrelevant
<m> irrelevant
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:MARK:X:SLIM ON
Switches on search limitation.
Manual operation: See "Search Limits (Left / Right)" on page 235