Remote Commands in the Receiver Application
R&S
®
ESW
550User Manual 1177.6298.02 ─ 08
If the marker is not yet active, the command first activates the marker.
Suffix:
<n>
.
Window
<m> Marker
Manual operation: See "Search Minimum" on page 238
CALCulate<n>:DELTamarker<m>:MINimum:RIGHt
This command moves a delta marker to the next higher minimum value.
The search includes only measurement values to the right of the current marker posi-
tion.
In the spectrogram, the command moves a marker horizontally to the minimum level in
the currently selected frame. The vertical marker position remains the same.
Suffix:
<n>
.
Window
<m> Marker
Manual operation: See "Search Next Minimum" on page 238
15.7.4.5 Marker Results
Commands to retrieve the marker position described elsewhere.
●
CALCulate<n>:DELTamarker<m>:X on page 539
●
CALCulate<n>:MARKer<m>:X on page 540
CALCulate<n>:DELTamarker<m>:X:RELative?................................................................. 550
CALCulate<n>:DELTamarker<m>:Y................................................................................. 551
CALCulate<n>:MARKer<m>:Y........................................................................................ 551
CALCulate<n>:DELTamarker<m>:X:RELative?
This command queries the relative position of a delta marker on the x-axis.
If necessary, the command activates the delta marker first.
Suffix:
<n>
.
Window
<m> Marker
Return values:
<Position> Position of the delta marker in relation to the reference marker.
Example:
CALC:DELT3:X:REL?
Outputs the frequency of delta marker 3 relative to marker 1 or
relative to the reference position.
Usage: Query only
Analysis