EasyManua.ls Logo

Samsung WEC8050 - APC Management Port Configuration

Samsung WEC8050
680 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WEC8500/WEC8050 (APC) Operation Manual v10.1 20
©Samsung Electronics America
WEC8500/configure #
Adding or Deleting an Account
The commands used to create or delete an account are as follows:
• mgmt-user [USERNAME] [USERLEVEL] description [DESCRIPTION]:
Adds a user
• no mgmt-user [USERNAME]: Deletes a user
Parameter
Description
USERNAME
User ID
USERLEVEL
User level
DESCRIPTION
Adds user information
WEC8050/configure# mgmt-user test 1 description “test account”
PASSWORD : *********
CONFIRM PASSWORD : *********
USER(test) CREATED.
WEC8050/configure# no mgmt-user test
user(test) deleted.
Retrieving Account Information
To check user account information use the ‘show mgmt-users’ command.
Changing Password
Use the ‘password’ command to change the password for your account.
The ‘password’ command must be executed in the highest user mode.
WEC8500# password
CURRENT PASSWORD : ********
NEW PASSWORD : ********
CONFIRM NEW PASSWORD : ********
APC Management Port Configuration
To connect to the APC remotely using telnet/SSH or web, it is necessary to set up an IP
address to the management port.
Set up the management port as follows:
1 Go to configure ‘mgmt0’ interface configuration mode of CLI.
WEC8500# configure terminal
WEC8500/configure# interface mgmt0
2 Set up an IP address.
WEC8500/configure/interface mgmt0# ip address 100.100.100.1/24

Table of Contents