WEC8500/WEC8050 (APC) Operation Manual v10.1 20
©Samsung Electronics America
WEC8500/configure #
Adding or Deleting an Account
The commands used to create or delete an account are as follows:
• mgmt-user [USERNAME] [USERLEVEL] description [DESCRIPTION]:
Adds a user
• no mgmt-user [USERNAME]: Deletes a user
WEC8050/configure# mgmt-user test 1 description “test account”
PASSWORD : *********
CONFIRM PASSWORD : *********
USER(test) CREATED.
WEC8050/configure# no mgmt-user test
user(test) deleted.
Retrieving Account Information
To check user account information use the ‘show mgmt-users’ command.
Changing Password
Use the ‘password’ command to change the password for your account.
The ‘password’ command must be executed in the highest user mode.
WEC8500# password
CURRENT PASSWORD : ********
NEW PASSWORD : ********
CONFIRM NEW PASSWORD : ********
APC Management Port Configuration
To connect to the APC remotely using telnet/SSH or web, it is necessary to set up an IP
address to the management port.
Set up the management port as follows:
1 Go to configure ‘mgmt0’ interface configuration mode of CLI.
WEC8500# configure terminal
WEC8500/configure# interface mgmt0
2 Set up an IP address.
WEC8500/configure/interface mgmt0# ip address 100.100.100.1/24