Managing Alarm and Event
The system alarms and events are saved into a system log and transmitted to an external
server according to the filtering policy. An alarm is managed in terms of occurrence and
release and an event is managed in the report format.
The alarm and event are managed according to group or level. Each group or level is
classified into the following item. You can select an item to retrieve.
Alarm and Event Group
Retrieves system alarm or event.
Retrieves performance monitoring alarm or event.
Retrieves AP related alarm or event.
Retrieves WLAN related alarm or event.
Retrieves WI-FI related alarm or event.
Retrieves security related alarm or event.
Retrieves network related alarm or event.
Retrieves interface related alarm or event.
Retrieves system engine related alarm or event.
Retrieves alarm or event list information.
Retrieves a critical alarm. A critical alarm is a system
log that could give a critical effect to a service.
Retrieves a major alarm. A major alarm is a system log
that could give a major effect to a service.
Retrieves a minor alarm. A minor alarm is a system log
that could give a minor effect to a service.
Retrieving Current Alarm
All the system alarms are basically recorded into a system log. The procedure of retrieving
current alarms is as follows:
Retrieving with CLI
To retrieve current alarms, execute the command as follows:
WEC8500# show alarm list all
1 network 2012-12-17 09:56:13 MAJ APC ge8 1301 NET Link dn AdminStatus[up]
OperStatus[down]
2 network 2012-12-17 09:56:13 MAJ APC xe1 1301 NET Link dn AdminStatus[up]
OperStatus[down]
3 network 2012-12-17 09:56:13 MAJ APC xe2 1301 NET Link dn AdminStatus[up]
OperStatus[down]
…