WEC8500/WEC8050 (APC) Operation Manual v10.1 44
©Samsung Electronics America
[admin status]
This is a command that makes the port not working. The ‘no’ parameter is used to restart
the port.
shutduown
no shutdown
[flow control]
This is a command that operates flow control to the port. The ‘no’ parameter is used to
stop the flow control.
flowcontrol on
no flowcontrol on
[switch port]
This is a command that changes the port to the L2 mode. The ‘no’ parameter is used to
change it to the L3 mode.
switchport
no switchport
[ip address]
This is a command that configures a static IP address. To delete the configuration, enter
the ‘no’ parameter.
• ip address {A.B.C.D/mask length}
• no ip address {A.B.C.D} {A.B.C.D}
• no ip address {A.B.C.D/mask length}
Configuration using Web UI
In the menu bar of <WEC Main window>, select <Configuration> and then select the
<Controller> <Ports> menu in the sub-menus. Operator can configure the ports.
The Ports initial window is shown below.
Operator can check the current status of each port.