DISOMAT Overview Control Elements
Display Meaning
xxxxxx
'Invalid'
Weight currently invalid
oooooo
'Overrange' (if 'Legal-for-Trade' parameter = Yes).
Internal weight acquisition continues, all switching functions, e.g. overload
checks, are active now as before.
When the 'legal-for-trade' parameter is set = No, the scale also shows
weights even above the maximum readings until it exceeds the rated range.
Afterwards, it shows 'invalid'.
With multi-range/multi-divisional scales, information on active field is
highlighted (range code).
1
to EN 45501
2. Event Messages
Never acknowledge event message before the cause of fault has
been remedied.
Sample: (Event messages are alternately displayed with weight information)
A0209:Powerfail
A1111-1:Cable broken
See BV-H2313: Chapter 'Event Messages'.
3. Menu Tree
The menu tree's functions are selected with the DIRECTION KEYS when the scale is
configured or parametered. Each of the menu functions have a number such as
4. Operator guidance/data input
Operator guidance is output or data is input as a text without leading numbers (such
as after starting a menu function)