Sequentix CIRKLON - Clock Mode

Sequentix CIRKLON
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sequentix Music Systems
Cirklon Sequencer User Manual
8-8
Clock Mode
In clock mode, the gate outputs can be used to generate a clock pulse based on a division of
the tempo clock, or a DIN-sync type run or reset signal.
When clock mode is selected the cv-num value is replaced by ppqn (pulses per quarter note).
This sets the clock division for the pulse output between 48 and 1.
Two further values of run and rst give the control signals needed to start or reset an attached
sequencer or drum machine.
Run gives a constant “on” signal when the sequencer is running.
Rst gives a short pulse when playback is started.
Note that the mclk send settings for the CV port must be configured on the MIDI port config
page for clock outputs to work.