Operating mode
The application situation can be preselected via the operating mode.
Standard - Suitable for most applications (see "Standard operating mode", page 24)
Transparent - Detection of transparent materials (see "Transparent operating mode",
page 24)
Dust and sunlight resistant - For applications with a lot of dust in the environ‐
ment or with strong sunlight (see "Dust- and sunlight-resistant operating mode",
page 25)
Scan mode
The scan mode describes different operating modes:
Standard - Operation with parallel beams
Cross beam function switching - For detecting smaller objects
Cross beam function measuring - For measuring smaller objects
High Speed Scan - For a short response time
NOTE
If High Speed Scan is deactivated in the energy options, High Speed Scan cannot be
activated.
For MLG-2 with 2m sensing range, the high measurement accuracy function
must be used for High Speed Scan .
You can use the Settings with object data option to set the minimum object size and
the minimum object length and enter the speed of the object through the detection
field.
Enter the speed of the object to be detected through the detection field in the
Object speed field.
Enter the height of the smallest object to be detected in the Height field.
Enter the length of the smallest object to be detected in the Length field. The
figure below the fields shows the entered values in proportion.