110
S2 User Handbook
16
Meterbridge Interconnect
An internal ribbon cable to the meterbridge is tted to the AUD output channel and appears
via the rear panel.
Word Clock Input Connector
This 75 ohm BNC socket is used for the word clock input, and has the following connections;
Inner: Signal.
Outer: Screen.
AES/EBU Sync Input Connector
This XLR 3 pin socket is used for AES/EBU Sync Input, and has the following connections;
Pin 1: Screen.
Pin 2: Phase.
Pin 3: Non-phase.
Channel Options, Jumper Settings and Presets
The AUD digital stereo output channel can be congured in a number of dierent ways
depending on the jumper options set on the board. The on-board processor’s software
is congured by jumpers J3 to J9 and channel identifying links. The AUD digital output
channel is identied by having links LK43 and LK45 tted. The AUD digital output with fader
is identied by having links LK43, LK45 and LK46 tted.
The standard options available are;
t 4FMFDUNPEFBOETBNQMFSBUF
t 4FMFDUPVUQVUTBNQMFTJ[F
t 4FMFDUDIBOOFMTUBUVTCJUT
t 4FMFDU"&4PS41%*'PVUQVU
t 4FMFDU"&4PS41%*'TZODJOQVU
S2ODAF/S2ODA DIGITAL OUTPUT AUD CHANNEL
WITH & WITHOUT MASTER FADER VERSION 1
S2ODAF/S2ODA DIGITAL OUTPUT
AUD CHANNEL WITH & WITHOUT
MASTER FADER VERSION 1