56
S2 User Handbook
S2CSGE/S2CSG STEREO LINE AND
GRAM CHANNEL WITH & WITHOUT EQ
S2CSGE/S2CSG STEREO LINE AND
GRAM CHANNEL WITH & WITHOUT EQ
8
Remote for Line 1 Input
The remote output for the Line 1 input can be used for a start and stop function wired to
other studio equipment such as CD or MD players. The default setting for J1 is none (not
tted), which produces a momentary remote contact. If your equipment requires a latching
contact for remote start then a jumper should be placed over pins 1 & 2 of J1. The remote
stop for Input 1 is always momentary.
Remote for Gram Input
The remote output for the Gram input can be used for a start and stop function for
turntables. The default setting for J2 is none (not tted), which produces a momentary
remote contact. If your equipment requires a latching contact for remote start then a
jumper should be placed over pins 1 & 2 of J2. The remote stop for the Gram input is always
momentary.
Continuous Momentary Start
The continuous momentary start function can be used for equipment that only ever
requires a remote start but not a stop. Placing a jumper over J3 pins 1 & 2 enables the
function. When enabled the operation of the ON button is changed to a continuous start
button. With the fader down, the button shows red. With the fader up, the button shows
green and each press of the ON button will trigger a momentary start from the remote
contacts. The default setting for J3 is none (not tted). It is not possible to congure a
latching remote start output when the continuous momentary start option has
been selected.
CUE/PFL Cancel
The CUE/PFL function is normally an alternate action. Press the button to select and press
again to de-select. However it may be desirable to have the fader up signal cancel a CUE/
PFL selection. Placing a jumper over J4 pins 1 & 2 will enable a previously selected CUE/PFL
function to be cancelled when the fader is up and the channel is ON. The default setting is
none (not tted).
Jumper J5 is not tted to this channel.
Timer Auto Start
The dual timer in the meterbridge can be set to start automatically from a fader open/
channel On signal. Jumper J6 determines which timer is set to auto-start. A jumper over pins
1 & 2 will start Timer 1, shifting the jumper to pins 2 & 3 will start Timer 2. The default setting
of J6 is none (not tted).
Jumpers J7 to J10 are not tted to this channel.
Presets
Two presets are available for adjustment of Line Input 1 gain, left and right. Presets, P1
(left), P2 (right) provide 16dB of gain adjustment, allowing an input range of +6dB to –10dB
referenced to 0dB output. The presets should be adjusted to give 0dB output for the chosen
source, and will cater for professional equipment with nominal output levels up to +4dB
and non-professional equipment with nominal output levels down to –10dBV. The levels are
preset for 0dB input when shipped.