Chapter 3 Signal Selection and Transitions
113
Signal Selection
Inhibiting cross-point button operations
For each cross-point button, you can temporarily inhibit operations.
Notes
This setting is cleared when you reset the control panel.
Assigning a button to the function of disabling cross-point button
operation
You can assign the button to be used for the operation to a user preference
button, in setup. The [Inhibit All Clear] function is also assigned to this button.
(See “Setting Button Assignments (Prefs/Utility menu)” in Chapter 19 (Volume
3).)
Buses for which operations can be inhibited
This setting applies to the auxiliary bus control block and the cross-point
buttons in each switcher bank.
For example, if you make the setting for one cross-point button in a switcher
bank, this inhibits operation of all cross-point buttons with the same number in
the following buses.
The corresponding name also disappears from the source name display.
Background A, background B
•Keys 1 to 8
Utility 1, Utility 2
DME utility 1, DME utility 2
External DME
To inhibit operation of a cross-point button
Hold down the button which “Inhibit Set” is assigned, and press the cross-point
button whose operation you want to inhibit.
The button you pressed flashes amber, and this makes the operation inhibited.
Notes
Even when you inhibit operation of a cross-point button, macro attachment
settings are still possible (see “Setting and Canceling a Macro Attachment” in
Chapter 16 (Volume 2)).
To clear a cross-point button operation inhibit setting
Hold down the button to which “Inhibit Set” is assigned, and press the button
whose operation is inhibited (flashing amber).
This clears the operation inhibit setting for the button you pressed.