Chapter 11 DME Operations
563
DME Special Effect Operations
a) Setting for SD 4:3, SD 16:9
b) Setting for HD 4:3, HD 16:9
• When other than Shape is selected
a) Setting for SD 4:3, SD 16:9
b) Setting for HD 4:3, HD 16:9
To limit the ripple range
1
Press [Range], turning it on.
2
Set the following parameters.
• When Radial or Shape mode is selected
a) Setting for SD 4:3, SD 16:9
b) Setting for HD 4:3, HD 16:9
• When Angular mode is selected
• When Both mode is selected
2 V Ripple center point in vertical
direction
–3.000 to +3.000
a)
–12.000 to +12.000
b)
Knob Parameter Adjustment Setting values
Knob Parameter Adjustment Setting values
1 H Ripple center point in
horizontal direction
–8.000 to +8.000
a)
–32.000 to +32.000
b)
2 V Ripple center point in vertical
direction
–6.000 to +6.000
a)
–18.000 to +18.000
b)
Knob Parameter Adjustment Setting values
1 Size R Amount of ripple modulation
along radius
0.00 to 100.00
2 Offset R Center of modulation range
along radius
–8.000 to +8.000
a)
–32.000 to +32.000
b)
Knob Parameter Adjustment Setting values
1 Size A Amount of ripple modulation along
periphery
0.00 to 100.00
2 Offset A Center of modulation range along
periphery
–8.000 to +8.000
Knob Parameter Adjustment Setting values
1 Size R Amount of ripple modulation
along radius
0.00 to 100.00
2 Offset R Center of modulation range
along radius
–8.000 to +8.000
a)
–32.000 to +32.000
b)